BIOMEDANA SOFT SENSORS · PREDICTIVE PROCESS INTELLIGENCE

Predict what you cannot continuously measure. Understand what drives it.

Combine biology, physics, mechanistic models, process data and machine learning to estimate hard-to-measure variables and surface emerging quality risks earlier.

From upstream cell culture and fermentation to downstream purification—predictions stay connected to evidence, uncertainty and process context.

SOFT SENSOR · FED-BATCH 24-071
MODEL v2.4 · ILLUSTRATIVE
ESTIMATED NOW4.18 g/L
PREDICTION INTERVAL±0.24
MODEL STATUSWithin domain
PredictedOffline assayInterval
NOW
Day 0Day 3Day 7Day 10Day 14
INFLUENTIAL INPUTSVCDFeedDOpHTemperature

Illustrative interface and data. A deployed model requires process-specific data, qualification and defined operating limits.

01 — EARLIER PROCESS VISIBILITY

Between the assay points,
the process keeps moving.

Soft sensors complement physical sensors and laboratory analytics. They make useful estimates available earlier and more frequently—without hiding the assumptions or limitations behind them.

01Estimate

Real-time and near-real-time process variables

02Predict

Titer, metabolites, biomass and selected quality attributes

03Detect

Process drift and emerging quality risk earlier

04Explain

Influential inputs, uncertainty and model applicability

05Connect

Historians, PAT, laboratory data and digital twins

06Govern

Model versions, review, monitoring and change control

02 — WHAT IS A SOFT SENSOR?

A virtual measurement built from signals, science and context.

A soft sensor uses mathematical, statistical, mechanistic or machine-learning models to estimate a variable that cannot be measured directly, continuously or economically with conventional instrumentation.

A bioreactor may continuously report dissolved oxygen, pH, temperature, agitation and gas flow while viable cell density, metabolites and product titer arrive only periodically. A qualified model can estimate those variables between laboratory measurements.

Inline process signals+Offline reference assays+Scientific relationships→Explainable estimate
with uncertainty

03 — HOW IT WORKS

From process data to
scientifically informed predictions.

Every estimate remains connected to its inputs, model version, process context and intended use.

01

Connect process data

Bring together bioreactors, equipment, historians, PAT instruments, laboratory systems and manufacturing records.

02

Contextualize the process

Align signals by batch, phase, material, equipment, sampling time and operating conditions.

03

Configure the model

Select statistical, mechanistic, machine-learning or hybrid methods for the intended use.

04

Generate predictions

Update estimates as suitable inputs arrive, with deployment-specific frequency and latency.

05

Explain and monitor

Evaluate performance, uncertainty, influential features, drift and recalibration needs.

04 — UPSTREAM + DOWNSTREAM

One soft-sensing foundation.
Different process questions.

UPSTREAM BIOPROCESSING

See growth, metabolism and productivity sooner.

  • Viable cell density and biomass
  • Glucose, lactate, glutamine and ammonia
  • Oxygen uptake and metabolic state
  • Product titer and harvest outlook
  • Process-specific quality-risk indicators
EXAMPLEPredict mAb titer before the next offline assay.

Combine cell density, feed history, DO, pH, temperature, metabolites and historical titer to track evolving productivity and inform harvest planning.

DOWNSTREAM BIOPROCESSING

Anticipate separation performance and recovery risk.

  • Chromatography breakthrough and loading
  • Recovery and elution characteristics
  • Membrane fouling and flux decline
  • Impurity and quality indicators
  • Intermediate and cumulative yield
EXAMPLEEstimate Protein A breakthrough before it occurs.

Combine loading history, UV, flow, resin characteristics and binding relationships to evaluate strategies and surface risk earlier.

05 — HYBRID ARCHITECTURE

Use the model the process needs.
Not the most fashionable one.

Bioprocess data can be limited and conditions change across materials, equipment and scale. BioMedAna supports multiple model families so scientific knowledge can constrain what data alone cannot.

01

Mechanistic

Mass balances, kinetics, substrate consumption, oxygen transfer and transport phenomena.

02

Statistical

PCA, PLS regression, chemometrics and multivariate process models.

03

Machine learning

Tree ensembles, Gaussian processes, support vector regression and neural networks.

04

Dynamic

State-space models, Kalman filtering and time-series estimation.

05

Hybrid

Scientific constraints and mechanistic states combined with data-driven correction.

06

Uncertainty-aware

Intervals, sensitivity, applicability-domain and out-of-distribution indicators where supported.

06 — APPLICATION CATALOG

Candidate applications across
process, performance and quality.

Each application needs suitable inputs, reference measurements, development and validation. Availability depends on the process, modality, instrumentation and deployment scope.

01

Cell growth & biomass

Viable and total cell density, viability, biomass, specific growth rate

Process-specific qualification required
02

Metabolites & nutrients

Glucose, lactate, glutamine, ammonia and consumption rates

Process-specific qualification required
03

Bioreactor performance

OUR, kLa, CER, respiratory quotient and metabolic state

Process-specific qualification required
04

Productivity

Product titer, specific productivity and predicted harvest titer

Process-specific qualification required

08 — VALIDATION + LIFECYCLE CONTROL

Accuracy matters.
Credibility and control matter too.

For regulated biomanufacturing, model performance must be evaluated against its intended use, limitations and impact on decisions.

01

Define

Intended use, inputs, reference methods, assumptions and acceptance criteria.

02

Evaluate

Held-out or prospective data, relevant operating conditions and data-leakage controls.

03

Qualify

Prediction error, uncertainty, sensitivity and performance outside the calibration domain.

04

Monitor

Residuals, input quality, process drift and triggers for investigation or recalibration.

05

Control

Model versions, training data, configuration, approvals and change records.

BioMedAna’s governance approach is designed to support applicable expectations under 21 CFR Part 11, GAMP 5 and relevant guidance for AI-enabled systems. Actual compliance and validation requirements depend on intended use, deployment and organizational procedures.

09 — DEPLOYMENT

Start with one measurable challenge.
Expand from demonstrated value.

PHASE 1

Use case

Target variable, decision and data readiness

PHASE 2

Develop

Select and configure the model approach

PHASE 3

Evaluate

Compare against independent references

PHASE 4

Integrate

Connect qualified outputs to workflows

PHASE 5

Monitor

Track performance and manage change

Typical data sourcesProcess historiansSCADA / DCS / MESRaman / NIR / PATLIMS and assaysBatch eventsEquipment and material metadata

Common questions about soft sensors

What is the difference between a physical sensor and a soft sensor?

A physical sensor directly measures a property through instrumentation. A soft sensor estimates a variable from other measurements and a mathematical or computational model.

Can soft sensors predict product quality attributes?

Selected attributes can be modeled when representative process data, analytical measurements and validated predictive relationships are available. Feasibility varies by attribute and process.

Do soft sensors require large datasets?

Not always. Mechanistic, statistical and hybrid models can help in data-constrained settings, but the data must still be suitable and representative for the intended use.

Can soft sensors work in real time?

Yes, when input data arrives with suitable frequency and latency and the model executes within the required timeframe. Some applications are better suited to near-real-time or phase-based predictions.

Can soft sensors be used in GMP manufacturing?

Potentially, subject to intended-use assessment, qualification or validation, data integrity, lifecycle controls and applicable quality-system requirements. They do not automatically replace an approved analytical method.

How are soft sensors different from digital twins?

A soft sensor estimates an unmeasured or infrequently measured variable. A digital twin represents selected aspects of a process for simulation, prediction and scenario analysis. They can work together.

Continue exploring predictive bioprocessing

See how BioMedAna Twin connects physics, biology and process evidence, or review the digital twin validation checklist for model scope, held-out testing and lifecycle considerations.

START WITH ONE HIGH-VALUE SIGNAL

Turn process data into predictive bioprocess intelligence.

Bring us a target variable, the available process signals and the decision you want to improve.